FLIR Series 2000 Thermal Imaging System                     Technical Specifications:    
 

 

FLIR System Field of View:

Mode AFOCAL Mag. Field - Of - View Units
Wide 1.9x 28.0 horizontal x 15.0 vertical Degrees
Narrow 7.5x 7.0 horizontal x 3.25 vertical Degrees

FLIR System Resolution:

Mode Resolution Units
Wide IFOV 1.41 Milliradians
Narrow IFOV 0.35 Milliradians

 

FLIR Minimum Resolvable Temperature Difference (MRTD) @ f0 (where f0 = 1/2(IFOV)):

Mode MRTD Units
Wide Field of View 0.16 Degrees Celsius
Narrow Field of View 0.18 Degrees Celsius

 

Equivalent f/Number = f1

 

Detector Specifications:

Characteristic Specification
Type HgCdTe / 2 x 4 TDI array, 8-12 microns
D* (Typical) 6 x 10^10 CM Hz^1/2 W^-1 (Peak Wavelength)
Cooling Mechanical Split Stirling, Closed Cycle

 

Video Specifications:  The video format conforms to the EIA RS-170 or optional CCIR Standard.

 

Visible Light Camera Specifications:

Monochrome CCD Camera Specifications:

Characteristic Specification
Format 1/2"
Pickup Element CCD Imager Sensor
Pixels 768H x 494V - RS-170 or 752H x 582V - CCIR
Video Output Signal 1.0V p-p 75 Ohm
TV Resolution (RS-170) 570H x 350V TV Lines
TV Resolution (CCIR) 560H x 420V TV Lines
Minimum Sensitivity 1 Lux

Color High Resolution CCD Camera Specifications:

Characteristic Specification
Format 1/2"
Pickup Element CCD Image Sensor
Pixels 510H x 492V NTSC or 500H x 582V PAL
Filter RGB pure color stripe filter
White Balance Preset for daylight
Video Output Signal 1.0V p-p 75 Ohm
TV Resolution (NTSC) 330H x 350V TV Lines
TV Resolution (PAL) 330H x 400V TV Lines
Minimum Sensitivity 5 Lux

 

6X Zoom Lens Specifications:

Characteristic Specification
Zoom Motor Driven
Iris Automatic Motor Driven
Filter Spot, Neutral Density
Focal Length 11.5 - 69 mm
Relative Aperture 1.4 - 1200
FOV Ratio 6X

Input Electrical Requirements:

Characteristic Specification
Input Voltage 24 VDC to 30 VDC
Nominal Current Requirements 7.5 Amps (Slewing)
Minimum Circuit 15 Amp (Recommended)

 

Mechanical Specifications:

Characteristic Specification
Field of Regard (Azimuth) +120 to -120 degrees
Field of Regard (Elevation) 0 to -180 degrees
Slew Rate 0 to 60 degrees per second
Field-of-View Change Time 0.12 Seconds

 

System Dimensions:

Item H x W x D (Inches)
PPS/IIU Assembly 19.3 x 16.8 x 15.8
IDP Module 4.8 x 7.0 x 12.3
Video Display Unit 8.7 x 10.1 x 10.6
System Control Unit 8.5 x 4.5 x 4.6
Tracker Electronics Unit (Optional) 7.0 x 8.5 x 13.5
Tracker Remote Unit (Optional) 3.2 x 3.2 x 9.3
Cables (Average) 120 (Length)

 

System Weights:

Item Pounds
PPS/IIU Assembly 53.8
IDP Module 11.0
Video Display Unit 14.8
System Control Unit 3.0
Tracker Electronics Unit (Optional) 25.0
Tracker Remote Unit (Optional) 1.6
Cables (Average) 9.0
Total for System w/o Tracker 91.6

 

Environmental Specifications:

Characteristic Specification
Operating Temperature -30 to +55 Degrees Celsius
Storage Temperature -55 to +70 Degrees Celsius
Humidity 95% (rh) @ 35 Degrees Celsius
Altitude Sea Level to 15,000 feet (limited by standard video display)
Vibration 2G @ 5Hz to 500Hz
Shock 20G

Click HERE to return to the main FLIR page.